1. After booting, do not stick to the front end bottle detector, how to let the bottles on the plate flow through the detector? Only use to open the labeling and mesh belt on the operating computer, the turntable is not opened, and the turntable can be solved after the bottle flows through the detector.
2. The labeling is too long, basically enclosing the bottle, there is only one way, that is, reduce the labeling speed. I pasted a 15ml. full bottle label, the speed was adjusted to 30 bottles / minute, faster will not work, roll the label all at once
3. Products with a relatively thin front end of the bottle, such as a dense bottle, when pasting, the front end bottle detector should be attached with a label to facilitate operation.
4. When changing the mold, rotate the transfer shaft, to the right slightly more than the rotating wheel, so that it is not easy to burst the bottle, another small secret recipe, if the test installation is not good, if there is no experience, it is best to choose powder, not solution. Because it is easy to clean up in case of a burst bottle. It should also be noted that the right end of the rotary transfer shaft must overwhelm the bottom press, and the two fixing screws on the left should also be tightened after adjusting the position.
5. Every time the label is changed, the position of each card wheel must be adjusted, so that each position of the label is on the same parallel surface as much as possible, so that the label is pasted a lot
6. Every time the label is changed, the label must be tested, which is actually a process of the machine recording parameters, and it is not possible to save effort just to do a standard test

7. When the standard test, it is best to have a leakage end length of 4-5 mm, it is not easy to roll if it is long, and it is not good if it is short.
8. The rubber wheels of the service should not be clamped too loosely or too tightly, and the label should not be twitched, and it is not advisable to use too much force. There is no clamping rubber wheel on the computer side, in fact, as long as you recover, it's good, don't desperately clamp the rubber wheel
9. When there is a missing label prompt, either the upper and lower positions of the label cannot be detected, and it is good to adjust the upper and lower positions of the detector. Or it is missing the standard, press the reset button at this time, and then click the inch on the parameter setting page to move the mark, and walk through the missing position
10. When going around the mark, there is a principle, that is, do not go back, from left to right, there will be no situation of going around the left and around to the right, the specific bypass, around twice is familiar.